Department of Electrical Engineering

 


 
    Year of Establishment
  July 2003
 
    Academic Programme: 4 yrs. B.Tech. programme in 
    Electrical
Engineering.

    H.O.D: Prof. Amitava Biswas.

   Contact Mail ID  ee_dept@aot.edu.in 

   Overview of Departmental Infrastructure

  • Class / Tutorial Rooms: 4 nos. @ 80 Sq.m. each.
  • H.O.D. Room & Departmental Office
  • Faculty Rooms
  • Departmental Internet Centre & e-Library
  • Amenities Area.

 

 Faculty Details of the department (click here)

 

 

 

     

 Departmental Laboratories (with area, major experimental facilities & equipments)

 
Basic Electrical Engineering Laboratory (127 Sqm.)
  • 1 HP-DC Shunt Motor                                               
  • 1 Phase Transformer 1.2kva
  • 8.nos. 1 Phase Variac    
  • 3-HP-Induction Motor (Crompton Greaves) 
  • 41-Ammeters,Voltmeters, Wattmeters,  Digital Multimeters                   
                                                                                               
Electrical Machines Laboratory (170 Sqm.)
  • 2 HP DC Compound Generator (GEC)
  • 2HP-DC Separately excited Generator  (Crompton-Parkinson)
  • 3-Phase Slip Ring Induction Motor  (Bharat -Bijlec Ltd)
  • 15 HP DC Series Motor (Crompton-Parkinson)
  • 2 HP DC Shunt Motor (Crompton-Parkinson)   
  • 3 Phase Cage Induction Motor
  • 3-Phase Slip Ring Induction Motor -Generator Set (2Kw)             
  • 4 nos AC Alternator with DC Motor Prime mover  
  • 2 nos.Phase Capacitor Start Induction Motor (NEC)   
  • 3 nos. 3 Phase Auto Transformer
  • AC V/ F Speed Control   (Micro Master 420 SIEMENS)
  • 98 nos Ammeter, Voltmeter, Wattmeter, Power Supply Units, 220/220 V Single phase Transformer.

 


Power System Laboratory (127 Sqm.)
  • Alternator with D.C. prime mover along with Active & Reactive Power Control Setup
  • A.B.C.D Parameter (TLP- 2094)
  • Power Circle Diagram (PCD-1409)
  • High Voltage Testing Set for Break Down Strength of Oil & Solids.
  • D.C. Distribution Network (DDA-904)
  • Measurement of earth resistance by Earth Tester (WACO-989111)
  • ON/OFF Time delay really with set up (Relay Type VTT-11 & VTT-12, ALSTOM)
  • CT & PT Characteristics study (AE)
  • Over Current, Earth Fault & Under Voltage Relay set (Relay Type) CDG-11, CDG-31, CDG-12, VDG-13, ALSTOM make.)
  • Motor Protection setup (Relay: Mot PRO ALSTOM)
  • Transformer   Protection setup (Relay: DDT-12AF, ALSTOM)
  • 6 nos. P-IV Workstation
  • MAT LAB Software.
  • Loss angle Resistivity measurement setup for Transformer Oil.
  • Insulator of different types.
  • ETAP Software (version 5.5.5)
Power Electronics Laboratory (127 Sqm.)
  • 6 nos. HP P-IV Computer
  • PSPICE Software
  • 20nos experimental set up for SCR (KCM-PE-28) TRIAC (KCM-PE-20) SCR, Triggering Circuit (KCM-PE-30A/30B/30C) Single phase. half controlled Bridge Converter (KCM /PE-14) Single-Phase Full Controlled Bridge converter (KCM/PE-6F), SCR Triggering Applications (KCM/PE-14)
  • 6nos 20MHz C.R.Os.
  • Digital and Analog Meters.


Thermal Science Engineering Laboratory (150 Sqm.)
  • DDEI Single Cylinder 4S Diesel Engine Test Rig with Rope Brake & Electrical Loading for Performance Test (combined unit)
  • DDEI 4S Single Cylinder 3 HP Petrol Engine Test Rig with Electrical & Rope Brake (combined)
  • 2nos. Bomb Calorimeter
  • Cleveland Apparatus
  • Pensky Martens Flash Point Tester (closed type)
  • ABEL Flash Point Apparatus (closed type)
  • Cloud & Pour Points Apparatus (Single tester, Double tester)
  • Performance study of Lanchasier Boiler
  • Performance study of Balecock & Willcox Boiler
  • Performance study of Cochran Boiler.
  • Performance study of Locomotive Boiler
  • Performance study of Vertical tubuler Boiler
  • Single cylinder 4S Diesel engine Model
  • Single cylinder 4S Petrol engine Model.


Electrical  Drives Laboratory (127 Sqm.)
  • Regenerative /    Dynamic Braking of DC Motor                                              
          Technical Specification:
                          DC Motor: ½ HP, 220V, 1500 rpm
                          Loading Arrangement: Brake Pulley
                          Drives: Braking arrangement
         1). Manual
         2). Through PC by own developed Software at any speed (speed control will be done by
               using  variac) Voltage, current measurement in PC.
  • Regenerate / Dynamic Braking of Ac Motor
          Technical Specifications:
                         AC Motor: ½ HP, 230 V, 50HZ, 1480 rpm
               Loading Arrangement: Brake Pulley
               Drives: Braking arrangement
        1). Manual
        2). Through PC by own developed Software at any speed (speed control will be done by
               using  variac) Voltage, current measurement in PC.
  • 5 Nos Compaq Presario (P-IV) Computer.
  • 5 Nos PSIM Software
 
 
 

 


© Academy of Technology 2008 | All rights reserved